GYTS Multi-Loose Tube Corrugated Steel Armored with rodent protection optical fiber cable
Product Description
Armored Loose Tube Single Jacket/SingleArmor fiber optic cable with fibers placed in loose buffertube stranded around central strength member.The cable core is protected with jelly to prevent water intrusion and migration,with a corrugated steel tape armorwhich provides rigid protection, rodent resistance and cover with a black Polyethylene out jacket.
Product Construction
Fiber:
2-288 fibers
Loose tube gel-filled
Armor:
Corrugated steel tape
Central Strength Member:
FRP or Steel Wire
Outer Jacket:
Black UV-and moisture-resistant polyethylene(PE)
Features
Up to288 fibers.
Loose tube gel-filled construction for superior fiber protection.
Corrugated steel tape armorto protect cable from mechanical damage and rodent protection.
UV and moisture-resistant design.
Applications
Backbones and Access.
Installed in ducts, underground conduits.
Option
Dry core structure is available, usd“-DC” suffix.
OpticaL Charateristics
Fiber Type
|
G.652
|
G.655
|
50/125^m
|
62.5/125^m
|
Attenuation
(+20X)
|
850 nm
|
|
|
<3.0 dB/km
|
<3.3 dB/km
|
1300 nm
|
|
|
<1.0 dB/km
|
<1.0 dB/km
|
1310 nm
|
<0.36 dB/km
|
<0.40 dB/km
|
|
|
1550 nm
|
<0.22 dB/km
|
<0.23 dB/km
|
|
|
Bandwidth
|
850 nm
|
|
|
>500 MHz-km
|
>200 Mhz-km
|
1300 nm
|
|
|
>500 MHz-km
|
>500 Mhz-km
|
Numerical Aperture
|
|
|
0.200±0.015 NA
|
0.275±0.015 NA
|
Cable Cut-off Wavelength cc
|
<1260 nm
|
<1450 nm
|
|
|
Structure and Technical Specifications
Fiber
Count
|
Nominal
Diameter
(mm)
|
Nominal
Weight
(kg/km)
|
Max Fiber
Per Tube
|
Max No. of
(Tubes+fillers)
|
Allowable Tensile Load
(N)
|
Allowable Crush Resistance
(N/100mm)
|
Short Term
|
Long Term
|
Short Term
|
Long Term
|
2~30
|
9.7
|
96
|
6
|
5
|
1500
|
600
|
1800
|
800
|
32~48
|
10.7
|
111
|
8
|
6
|
1500
|
600
|
1800
|
800
|
50~72
|
11.6
|
136
|
12
|
8
|
2000
|
600
|
1800
|
800
|
74~96
|
13.0
|
166
|
12
|
10
|
2000
|
600
|
1800
|
800
|
98~144
|
15.1
|
228
|
12
|
12
|
2500
|
600
|
1800
|
800
|
Note : This datasheet can only be a reference, but not a supplement to the contract. Please contact our sales people
for more detailed information.
We produce and test cable comply with following standard
Mechanical Performance
|
Max Tension Performance
|
IEC 60794–1-2-E
|
Max. Operation Tension
|
IEC 60794–1-2-E1
|
Crush Test
|
IEC 6079 –1-2-E3
|
Impact Test
|
IEC 60794–1-2-E4
|
Repeated Bending
|
IEC 60794–1-2-E6
|
Torsion Test
|
IEC 60794–1-2-E7
|
Cable bend
|
IEC 60794–1-2-E11A
|
Attenuation Coefficient
|
ITU-T G.652
|
Structural Test
|
IEC-60793-1-20
|
Environmental Performance
|
Temperature Cycling
|
IEC 60794–1-2-F1
|
Water Penetration
|
IEC 60794–1–2-F5B
|
Filing Compound Flow
|
IEC 60794-1-E14
|